Purpose
Apollon series is PEMFC testing station designed to meet power range from 4 kW to 10 kW. It is suitable for testing single cell of large area as well as for experimenting with fuel cell stack at defined working condition of middle range power.
Capabilities
Custum designed lines are provided. Anode and cathode lines are humidified by advanced system. Provided with multivoltage monitor, multitemperature monitor for fuel cell stack analyses, cooling system 4 – 10 kW / 95°C or 200°C., EL load and/or potentiostat.
Fully automated and unattended operation
All functions of testing station are controlled by computer and it is ready for remote control: especially all valves, heaters, mass flow control, pressure control, humidity control. System is fully automated enables unattended operation.
Safety
System contains safety procedures as nitrogen purge and emergency shut down. Working range as voltage and current of the cell, all temperature sensors are compared with safety limits that can be set. There are two levels of limits. Hydrogen leak sensor is installed.
Apollon series | |
---|---|
Power range | 4 kW – 10 kW |
Flow rates | Anode: 100-200 slpm, Cathode: to 250-800 slpm |
Gas humidification | Dew point up to 90°C, dry gas by-pass (manual or automatic) |
Operating temperature | Max 120°C / 200°C; 3 Bar |
Cooling system | Cooling system up to 4-10 kW 95°C/200°C |
Loads | Different variants meet the power range. |
Potentiostat | Different variants from 5V/20A to 10V/100A |
Safety | Automatic nitrogen purge, voltage and current limits, hydrogen detector, safety interlocks, blackout protection. |
Dimensions | 1200x1200x1800 mm |
Cell or Stack connectivity | |
Heaters / Cooling | Provision of two independent heaters 110-230 V controlled by PID with TC disconnect protection. Coolant connection. |
Compressed air | Up to 15 Bar with manual safety regulator. |
Voltage and TC senses | Ready for 4 points measurement for single cell or multichannel voltage and temperature measurement for stack |